Large industrial ceiling fan preparation before welding

Views : 260
Author : JU LAI
Update time : 2023-06-13 08:14:33

Large industrial ceiling fans are composed of various components, and the main body structure is mostly welded with aluminum alloy materials. To ensure the quality of the welding process, it is necessary to prepare the aluminum alloy before welding, especially by removing oil and oxide from the surface.

Regarding oil removal: Since aluminum has a high solubility in the molten state, it is recommended to remove the oil from the welding area to reduce or eliminate the possibility of porosity. Various methods can be used to remove oil, for example, using a clean cloth without degreasing solvent. This method is very effective.

A mild alkaline solution is also an effective cleaning agent. The fan components that need to be cleaned can be sprayed with a solution or soaked in a container containing a solution. Because such cleaning agents are usually water-based, it is important to thoroughly rinse and dry after cleaning.

Many suppliers sell acidic cleaning solutions to clean aluminum parts. These cleaning solutions are usually effective and can remove excess oxide. However, these are acidic and some may contain ammonium fluoride, so be careful when using and handling them. The workpiece should be thoroughly rinsed and dried again.

Regarding oxide removal: Removing the oxide layer before welding large industrial ceiling fan aluminum alloy components is important for two different reasons. The melting temperature of aluminum oxide is higher than that of aluminum. If the oxide layer is too thick during welding, it may cause oxide defects in the weld. Oxides have permeability and may introduce water vapor in humid environments. If the welding material is not prepared properly, it may cause porosity in the welded parts.

Several methods can be used to remove oxide. The most commonly used method is to use a stainless steel wire brush. The wire brush should be clean and not previously used for cleaning other than aluminum parts. The wire brush should also be relatively flexible, and light pressure should be applied when using it to avoid unnecessary surface roughness of aluminum workpieces. Oxide can also be removed by immersing the parts in a strong alkaline solution, but these solutions are corrosive and may corrode the surface of aluminum alloy parts, so be especially careful when using them in some industries.

Therefore, before welding the aluminum alloy components of large industrial ceiling fans, it is necessary to first remove surface oil and then remove oxide. Only in this way can the welding work be ensured without unnecessary quality defects.

Related News
Read More >>
How many blades are good for HVLS industrial fans? How many blades are good for HVLS industrial fans?
Jun .30.2023
The HVIST fan was invented by a joint venture between a US and a Chinese company in 1999. After almost 20 years of development, various industrial fans with different numbers of blades have emerged. Currently, domestically and internationally, industrial fans mainly come in three-blade, four-blade, five-blade, six-blade, and eight-blade configurations. In theory, the more blades a fan has, the greater the airflow. However, since industrial fans are generally larger in size, more blades also mean more weight and increased safety risks. Therefore, it is necessary to strike a good balance between airflow and quality. Currently, industrial fans with five or six blades are most popular on the market. These two types are also the main products promoted abroad and have been market-certified for over a decade. As long as manufacturers strictly require high quality and safety for the blades, they can meet market demand.
Large fans in the indoor basketball hall improve ventilation and cooling Large fans in the indoor basketball hall improve ventilation and cooling
Jun .27.2023
With the promotion of nationwide fitness, various communities have built indoor basketball courts of different sizes. However, the large span, high height, and relatively sealed building structure of basketball courts pose great challenges to ventilation and cooling. In recent years, many venue constructors have found that large fans (big ceiling fans) can perfectly solve the ventilation and cooling problems, which are tricky for indoor basketball courts.
Principles to be followed in designing industrial large fan blades Principles to be followed in designing industrial large fan blades
Jun .27.2023
Industrial large fans have been imported into China from abroad, and batches of industrial fan manufacturers have been continuously researching, developing, and producing a full range of large industrial fan series products suitable for various environmental improvements in China. High-quality large fans are often built on good materials and unique advanced designs. The fan blades of industrial large fans are made of 5052 aviation aluminum, and unique blade designs can maximize the advantages of large fans and meet the needs of different users. When designing fan blades, industrial fan manufacturers need to follow certain principles.